Showing results: 31 - 45 of 48 items found.
-
784253-01 -
NI
The CP500X is a coaxial passive probe with fixed 10X attenuation for oscilloscopes that provide 1 MΩ input impedance. It is 1 meter in length. The CP500X attaches to BNC connections on both the signal input and instrument sides.
-
784254-01 -
NI
The CP400X is a coaxial passive probe with fixed 10X attenuation for oscilloscopes that provide 1 MΩ input impedance. It is 2 meters in length. The CP400X attaches to BNC connections on both the signal input and instrument sides.
-
67A -
Picoprobe
A coplanar probe with patented flexible tips, the MODEL 67A microwave probe sets new standards in microwave probing performance. Using low loss coaxial techniques, the Model 67A achieves an insertion loss of less than 1.1 db and a return loss of greater than 14 db through 67 GHz.
-
LVRD10 Series -
Omega Engineering, Inc
The LVRD10 Series guided wave radar transmitters provide continuous level measurement with a 4 to 20 mA signal output. Offered in single rod, coaxial, or weight & cable probes in 3 or 6 foot lengths
-
Model No. 200-04 -
Srico, Inc.
SRICO Model No. 200-04 Photonic Electric Field Sensor System has the ability to measure electric field with minimal disturbance to the field. The lightweight fiber-optic cables allow for easy placement of the E-field probe, allowing it to be unencumbered by the use of heavy coaxial cables that may disturb the field being measured. The dielectric E-field probe is electrically passive.
-
Series S200, S300, S400, and S500 -
AlphaTest Corp.
Test Probes for fine-pitch applications: CSP, BGA, SiP, SoC, flex-circuits, micro pcb, sub-mm center-to-center spacing, half mm, quarter mm spacing. Excellent for use in sockets, fixtures, and contactors for semiconductor testing and in coaxial installations.
-
50A -
Picoprobe
The GGB Industries, Inc., MODEL 50A probe sets new standards in microwave probing performance. Using low loss coaxial techniques, the Model 50A achieves an insertion loss of less than 1.0 db and a return loss of greater than 18 db through 50 GHz.
-
40A -
Picoprobe
The GGB Industries, Inc., MODEL 40A microwave probe sets new standards in microwave probing performance. Using low loss coaxial techniques, the Model 40A achieves an insertion loss of less than 0.8 db and a return loss of greater than 18 db through 40 GHz.
-
ICFP -
Ardent Concepts, Inc.
Ardent’s ICFP is a next generation coaxial cable termination toolkit for advanced system design de-embedding, de-bugging, and calibration. Designed for the lowest loss access to signal paths on an IC circuit footprint, this solution is a simple, cost effective alternative to expensive probers and x-y tables for Engineers who need to probe multiple signals at once.
-
PHD-3001A -
High Power Pulse Instruments GmbH
*Pulse force and pulse sense fixed pitch and flexible pitch RF probing solution for TLP/VF-TLP/HMM on-wafer measurements using Picoprobe™ Model 10*High peak current capability 80 A (100 ns)*DC – typ. 7 GHz bandwidth*Isolated probe-head ground shield for high pulse sense common mode signal rejection*Including fixed pitch replacement probe tip 50 Ω, right, 100 µm pad pitch*Including fixed pitch replacement probe tip 5 kΩ, left, 100 µm pad pitch*Including flexible pitch clamps plus 10-5k(0502)-125-W-1 and 10-50/30-125-W-1 replacement probe tips*True coaxial high-resolution 80:1 rotary probe-head for accurate probe tip adjustment
-
Teseq AG
The GTEM cell is a frequency extended variant of the traditional TEM (Transverse Electro-Magnetic) cell. The GTEM cell is, in principle, a tapered coaxial line (offset septum plate), which is terminated by a combination of discrete resistors and RF absorbers to achieve a broadband match. Designed for EMC applications, calibration of antennas/field probes, test and measuring of mobile phones and screening measuring of material.
-
Cryogenic Ltd.
The Resistivity System allows the user to make Resistivity and Hall Effect measurements in the range of to M. Samples are mounted on special platforms inside the VTI with contacts made to the sample according to the customer's requirements. Connections at the top of the probe are made via Fischer Connectors or Coaxial Cables. Keithley source and measurement electronics are provided with the system. These are fully controlled using the Measurement System Software.
-
PHD-4001A -
High Power Pulse Instruments GmbH
*Electrically isolated probearm kit for VF-TLP, TLP, HMM, HBM force and sense probingbased on the GGB Picoprobe Model 10 replacement probe tips*Buried coaxial cable channel for thermo-chuck in isolated chamber temperature measurements*Compatible with GGB Picoprobe Model 10 replacement probetips*Compatible with all standard micropositioner interfaces*High precision rotation of the probearm by backlash-free 80:1 gear*Rugged stainless steel design*SMA connectors
-
PH-100/120 -
Pansco, Ltd
The Lantracker is a network tester, pin-by-pin cable tester, and tone generator all in one. As a network tester, it detects whether a network is active or inactive and displays network speed (10/100/1000 Mbps) in either case. It also flashes the network hub or NIC’s port light corresponding to the cable it is connected to, to show the cable’s port number. As a cable tester, it performs loop-back or remote tests of network, data, voice, and coaxial cables, displaying the results on a pin-by-pin LED display which moves from pin to pin automatically or manually. The Lantracker can be used to test cable or shield integrity, testing network function and speed, and tracing cable using its tone generator function (tone probe not included). Includes an adaptor for testing coaxial-F cable. Uses 1 9V battery.
-
72-8500 -
Tenma
This tone & probe set is a basic necessity for anyone running data, voice or any other low voltage cable. It is also suitable for tracing alarm, coax or speaker cables which are already installed.